Professional Nailfold Capillary Microcirculation Microscope Test Machine

Save $83.00
ALISASKU: c240529010443

Price:
Sale price$208.00 Regular price$291.00
Stock:
In stock
Ships to

60-Day Buyer Protection
Money Back Guarantee
Return Policy
15 Days Easy Return
Security Guaranteed

Description

Report Item

Portable Nailfold Capillaroscopy Microcirculation Test Machine




Functions of microcirculation test machine :

Nailfold Capillaroscopy Microcirculation Test Machine is a new photoelectric instrument of non-invasive and no side effects,whice is used to check the nailfold microcirculation of human body.It’s widely used in clinical for diagnosising the early microcirculation change, Condition forecast, curative effect judgment and prognosis estimation of many diseases (such as heart head blood-vessel, high blood pressure, stroke, diabetes, rheumatoid arthritis, etc.).




Structure of Microcirculation Test Machine 

1.  8 inch monitor           

2.  imported chip CCD       

3.  fine handwheel   

4.  coarse handwheel                       

5.  platform lateral movement        

6.  longitudinal movement of the platform                      

7.  finger hold                                 

8.  image spot adjustment ( could totate from left and right )



Usage of microcirculation test machine

1. Fix the screen on the top of the mechanical machines.



2. Plug in the power line and vidao line to the interface of the base.



3. Connect the plug, the plug shows green lights. Press the "Power" button of the screen, wait 3 seconds, the screnn will light.


4. Paint three drops of oil at the position of the intersection of the ring finger nails and skin. Put the oil coated finger in finger hold.


5. Adjuet the coarse hand wheel, when the screen displays images, then adjust fine handwheel. Picture becomes clearer. The bigger one is the coarse adjustable wheel and the small wheel is the fine handwheel. When the machine is about 2-3cm away from the finger, there will be a transparent image on screen.


6. Then, adjuet platform lateral movement handwheel to et a correct position of the first line of the vessel( capillary tube ) and adjuet the fine coarse handwheel to get a clear picture of the vessel. Your fingers will move from left to right on the double loading platform. So try to find the first line of vessels by rotating the platform lateral movement handwheel to change the position of the finger. And finally rotate the fine handwheel ( the position is showed in the structure ) to get a clear picture of the vessels.



7. If there is spot on the screen, rotate the carmera right and left to eliminate it.




Detailed images of microcirculation test machine :



You may also like

Recently viewed